Thermal analysis

Where it is

Not a setup-tree node. Embedded in the application.

Controls

ANALYSIS

Solver

  • Control: choice (ComboRow)
  • Options: code_aster, elmer

Two solvers, one case. They agree to four decimal places on the worked example, so a disagreement is worth looking at rather than averaging. Elmer needs its own component installed and converts the mesh first; code_aster reads it directly.

Analysis type

  • Control: choice (ComboRow)
  • Options: Steady, Transient

The in-app guidance depends on the case:

  • How the temperature gets there, and how long it takes. Needs a density and a heat capacity.
  • Where the temperature ends up once nothing is changing any more.

Start from

  • Control: value (ValueField)
  • Unit: K
  • Value modes: none (plain entry)
  • Shown when: ThermalState.analysis === "Transient"

The whole body at t = 0. Without it the solve starts from absolute zero, which converges and answers a different question.

Run for

  • Control: value (ValueField)
  • Unit: s
  • Value modes: none (plain entry)
  • Shown when: ThermalState.analysis === "Transient"

Time step

  • Control: value (ValueField)
  • Unit: s
  • Value modes: none (plain entry)
  • Shown when: ThermalState.analysis === "Transient"

HEATING FROM A CURRENT

Joule heating

  • Control: choice (ComboRow)
  • Shown when: root.emStudies.length > 0

One-way: the current heats the part and the part getting hot does not change the current. The electromagnetics study has to have been RUN — this reads the file it wrote.

HEAT SOURCES

+ Add a heat source

  • Control: action (ToolButton2)

READINESS

Write every

  • Control: value (ValueField)
  • Unit: steps
  • Writes: sif/Output Intervals
  • Value modes: none (plain entry)

How many time steps pass between writes. Every step on a long transient is a great deal of disk for a result nobody reads at that resolution.

Time-scheme order

  • Control: value (ValueField)
  • Writes: sif/BDF Order
  • Value modes: none (plain entry)

BDF order for a transient run. 1 is backward Euler - stable and heavily damped, so a coarse step flattens the peak the study was run to find. 2 is the usual remedy.

Conditional and repeated groups

Per item in ThermalState.sources

repeated once for every entry in ThermalState.sources

Region

  • Control: choice (ComboRow)

Remove

  • Control: action (ToolButton2)

Power density

  • Control: value (ValueField)
  • Unit: W/m³
  • Value modes: none (plain entry)

Per cubic metre, not total. A 5 W part in a 10 cm³ volume is 500 000 W/m³.

Problems reported against this step

The application reports no problems against this step.